High quality hydraulic equipment manufacturers!
TELL:+8613184968882

stern plate hydraulic cylinder Sold to Algeria

Release time:2023-11-09 08:46:27 Hits: Current position: Home > News

This article mainly introduces:

Algeria hydraulic cylinder,stern plate hydraulic cylinder manufacturer,stern plate hydraulic cylinder

Algeria stern plate hydraulic cylinder

(Algeria stern plate hydraulic cylinder,produced by Hengyu Hydraulic Co., Ltd)

stern plate hydraulic cylinder are widely used in Algeria,because of powerful torque,simple structure and reliable operation,clever hydraulic energy conversion.So our company has designed stern plate hydraulic cylinder for customers from Algeria.

Introduction to stern plate hydraulic cylinder:

Before the stern plate hydraulic cylinder is removed, the system should be unloaded, the loop pressure is zero, the oil source should be cut off, and the oil port should be blocked after the oil port distribution pipe is loosened.

stern plate hydraulic cylinder seal leakage causes and countermeasures: a. Loose tie rod nut will cause leakage, tighten the tie rod nut according to the torque requirements of tie rod nut, test no leakage can continue to use. b. Pressure exceeding the limit will also cause leakage. Replace the stern plate hydraulic cylinder seal and re-tighten the tie rod nut to reduce the pressure to the nominal pressure range of the stern plate hydraulic cylinder. c. The stern plate hydraulic cylinder seal is extruded, if the O-ring is obviously extruded at the stern plate hydraulic cylinder seal, replace the stern plate hydraulic cylinder seal.

If the stern plate hydraulic cylinder operation failure, you can start from these aspects to troubleshoot: (1) the hydraulic system control pressure is too low. The throttling resistance in the control line may be too large, the flow valve is improperly adjusted, the control pressure is inappropriate, and the pressure source is disturbed. At this time, the control pressure source should be checked to ensure that the pressure is adjusted to the specified value of the system; (2) Air enters the hydraulic system. Mainly because there is a leak in the system. At this time, check the liquid level of the hydraulic tank, the seals and fittings on the oil suction side of the hydraulic pump, and whether the oil suction filter is too dirty. If so, the hydraulic oil should be replenished, seals and fittings should be treated, and the coarse filter element should be cleaned or replaced. (3) The initial action of the stern plate hydraulic cylinder is slow. In the case of low temperature, the hydraulic oil viscosity is large, poor flow, resulting in slow stern plate hydraulic cylinder action. The improvement method is to replace the hydraulic oil with better viscosity and temperature performance If the stern plate hydraulic cylinder is weak and cannot push the load, please check the internal leakage problem. The internal leakage of the stern plate hydraulic cylinder includes the leakage caused by excessive wear of the stern plate hydraulic cylinder block seal, the piston rod and the seal cover seal and the piston seal. The cause of sealing leakage between the piston rod and the seal cover is that the seal is wrinkled, squeezed, torn, worn, aging, deterioration, deformation, etc., and a new seal should be replaced at this time. The main cause of excessive piston seal wear is improper adjustment of the speed control valve, resulting in excessive back pressure and improper seal installation or hydraulic oil contamination. The second is that foreign bodies enter the assembly and the quality of sealing materials is not good. The result is that the action is slow and weak, and in serious cases, it will cause damage to the piston and stern plate hydraulic cylinder, and the phenomenon of "pulling the stern plate hydraulic cylinder" appears. The treatment method is to adjust the speed control valve, and the necessary operations should be done according to the installation instructions.

When the stern plate hydraulic cylinder is installed on the main engine, the oil port piping part and the guide sleeve should be checked for oil leakage in the running test, and the earring and the middle hinge shaft bearing should be refueled.

Answers to some questions about stern plate hydraulic cylinder:

Why does excavator cylinder oil leak?
Under normal circumstances, the leakage of hydraulic cylinders is divided into internal leakage and external leakage. The external leakage is generally due to damage to the oil seal at the extended end of the piston rod and needs to be replaced. Internal leakage is generally because the oil seal on the piston is damaged, you can try to replace the oil seal here, if the replacement will also leak, then check whether there is damage to the inner wall of the cylinder.

What are the causes of hydraulic cylinder oil leakage?
First, between the piston rod and the guide sleeve: 1, the cylinder force is not good, there is a radial force between the piston rod and the guide sleeve there is a partial load, so that the oil seal is worn early, causing oil leakage. 2. The ambient temperature of the piston rod is high, especially radiant heat, and the oil seal aging is fast. 3. Whether the oil seal is selected correctly; Check whether the oil seal is damaged during installation. 4, guide sleeve and piston rod matching tolerance is correct. Second, between guide sleeve and cylinder: 1. Whether the O-ring on the guide sleeve is installed correctly, pay special attention to the O-ring can not "roll", especially some O-rings are die-pressed with a die-closing line. Third, common problems: 1, guide sleeve, cylinder, piston rod concentricity is poor. Fit tolerance is correct.